Home > Testing Project
Testing Project
Testing Project
The laboratory has various advanced testing equipment and instrument, complete quality assuring system, many famous professors and scholars, and a team with high level of technique. Based on science、fair、security and high-effect,the lab can successfully complete various environmental adaptability and reliability qualification test、high-acceleration life test、high-effective environment stress test、step stress test、production environment acceptance test、reliability increasing test、reliability qualification test and special tests. And it can satisfy with GJB150、GJB899、GJB360、GB/T2423 and some relative criteria of such as electron、electrical appliances、vehicle industries and so on.
  Equipments Main Parameter Criteria Testing Projects Remark
01 GDW/JB-10Three comprehensive environmental testing system (DC-10000-100 ELECTRONIC VIBRATION SYSTEM) Temperature Range:+85℃~-60℃Temperature Variation Velocity: 10℃/min
Humidity Range: 30~98%RHEfficient
Volume: 10m3 (2m×2.5m×2m)
Shaker: 100 KN Force
GJB899 Reliability Qualification and Acceptance TestsGJB150 Equipment Environmental Testing MethodsGB2423 Basic Environmental Testing Regulations Temperature、Humidity、Vibration Three comprehensive reliability tests
High-temperature test
Low-temperature testTemperature Recurrence test Vibration test
Shock test
 
02 KGDW-1
Fast-Temperature-Variation comprehensive environmental Testing system (DC-3200-36 ELECTRONIC VIBRATION SYSTEM)
Temperature Range:+150℃~-80℃
Temperature Variation Velocity: 60℃/min
Efficient Volume: 1m3 (1m×1m×1m)
Shaker: 32 KN Force
GJB899 Reliability Qualification and Acceptance Tests
GJB150 Equipment Environmental Testing MethodsGB2423
Basic Environmental Testing Regulations GJB1032
electronic products environment stress filtration test
Environment   Stress Filtration、Temperature Shock、Fast Temperature Variation Three-direction fixture included to realize three directions vibration to the test sample
03 GDW/JBZ-3m3 Three comprehensive environmental testing system (DC-5000-50 ELECTRONIC VIBRATION SYSTEM) Temperature Range:+85℃~-60℃
Temperature Variation Velocity: 12℃/min
Humidity Range: 30~98%RHEfficient
Volume: 3.4m3 (1.5m×1.5m×1.5m)
GJB899 Reliability Qualification and Acceptance Tests
GJB150 Equipment Environmental Testing Methods
GB2423 Basic Environmental Testing Regulations
Temperature、Humidity、Vibration Three integrated reliability tests
High-temperature test
Low-temperature test
Temperature Recurrence test
 
04 KGDW-1m3
Fast-Temperature-Variation environmental Testing system
Temperature Range:+120℃~-80℃
Temperature Variation Velocity: 5℃/min~30℃/min
Humidity Range: 30~98%RH
Effective Volume: 1m3 (1m×1m×1m)
GJB899 Reliability Qualification and Acceptance TestsGJB150 Equipment Environmental Testing MethodsGB2423 Basic Environmental Testing Regulations GJB1032 Electronic Products Environment Stress Filtration Test High-temperature test
Low-temperature test
Temperature Recurrence test
Temperature Shock
 
05 SETH-Z101U-V-1m3 Three comprehensive environmental testing system (DC-3200-36 ELECTRONIC VIBRATION SYSTEM) Temperature Range:+150℃~-60℃
Temperature Variation Velocity: 1~2℃/min
Humidity Range: 30~98%RHEffiective
Volume: 1m3 (1m×1m×1m)
Shaker: 32 KN Force
GJB899 Reliability Qualification and Acceptance Tests
GJB150 Equipment Environmental Testing Methods
GB2423 Basic Environmental Testing Regulations
Temperature、Humidity、Vibration Three integrated reliabilitytests
High-temperature test
Low-temperature test
Temperature Recurrence test
Vibration test
Shock test
 
06 400 KN electronic Shaker
(DC-40000-400 electronic vibration system )
Rated sine force: 392KN
Rated random force: 392KN
Frequency Range:2-2000Hz
Max. Acceleration: 100g
Max. Load:6000kg
Max. Displacement:51mmp-p
GB2423 Basic Environmental Testing Regulations
GJB150 Equipment Environmental Testing Methods
   
07 200 KN electronic Shaker(DC-20000-200/SC-1515 vibration system & slip table) Force: 196kNFrequency Range:2-2200HzMax. Acceleration: 980m/s2Max. Load:2000kgMax. Displacement:51mmSlip table size: 1500×1500 mm GB2423 Basic Environmental Testing RegulationsGJB150 Equipment Environmental Testing Methods Vibration tests
Shock tests
Characteristic:large force; good anti-tilt moment; realize the normal function of high barycentre sample
08 100 KN electronic Shaker
(DC-10000-100/SC-1010 vibration system & slip table)
Force: 98KN
Frequency Range:2-2200Hz
Max. Acceleration: 980m/s2
Max. Load:2000kg
Max. Displacement:51mm
Slip table size: 1000×1000mm
GJB150 Equipment Environmental Testing Methods
GB2423 Basic Environmental Testing Regulations
Vibration tests
Shock tests
 
09 50 KN electronic Shaker
(DC-5000-50/SC-1515 vibration system & slip table)。
Force: 50KN
Frequency Range:2-2500Hz
Max. Acceleration: 980m/s2
Max. Load:1000kg
Max. Displacement:51mm
Slip table size: 1500×1500mm
GJB150 Equipment Environmental Testing Methods
GB2423 Basic Environmental Testing Regulations
Vibration tests
Shock tests
 
10 30 KN electronic Shaker
(DC-3000-36/SC-0606 vibration system & slip table)
Force: 30KN
Frequency Range:5-2500Hz
Max. Acceleration: 980m/s2
Max. Load:500kg
Max. Displacement:51mm
Slip table size: 600×600 mm
GJB150 Equipment Environmental Testing Methods
GB2423 Basic Environmental Testing Regulations
Vibration tests
Shock tests
 
Next page